Water Heater Safety Precautions

Posted by on Dec 3, 2013 in Water Heater Repair Wichita

Effectively preserving ones water heater is important not so it works to its full potential and can save some energy cash, however for safety issues too. Yes, it can blow up – it doesn’t take place too commonly for residents, however clearly this is something that Water Heater Repair Wichita¬†doesn’t wish to have take place to you!

Vents
Venting can be kind of technical but we will go over the essentials below. The vent must be the exact same diameter as the draft diverter of the water heater tank. It is expected to go up and out (for atmospherically vented heaters). Not other directs like up, down, up and out. For direct-vent water heaters, the vent need to go out a side wall. As for power-vent heaters, the fan blows the fumes out, so there is some flexibility in the instructions they are vented.

Any roofing or wall that the vent goes through ought to be a double wall. The single wall pass throughs ought to be screwed with 3 screws per section. If these fundamentals are not adhered to, the vents can fall apart gradually and carbon monoxide can cause major issues within ones home. Naturally we don’t desire that to take place!

The only other issue with ventilation is that of backdrafting. The fumes can eat the vents with acid condensation. If plenty of this gets on cold piping and the water heater it will not be a great situation for a correctly working water heater. If the fumes go back inside the instead of being appropriately vented outside, the fumes can enter the living locations of the home. Soot troubles can emerge too.

Dielectric Connectors
The steel water heater is linked to cooper pipes by the dielectric connectors. When two these two metals are assembled in water electrolysis occurs. The process corrodes one metal away to secure the other. This process is vital in safeguarding the inside of the water heater. Assessment for leaks ought to be done where the connections are made.

Temperature and Pressure Relief Valve
This is kinda of an essential part of the water heater, for it helps see to it the darn thing does not explode under pressure if the temperature level exceeds the appropriate limitations the water heater is designed for. Once a year (at least) the T&P valve should be checked to ensure, it is working properly, for they can be susceptible to failure. Simply pulling up on the handle water needs to flow easily out and stop when the handle is released. If it simply runs or trickles, or does nothing at all, it will should be replaced.

The drain lines for the T&P line ought to not be directed up, because water doesn’t stream uphill too well. Make sure it goes down and or out please. If water is running out the drain line regularly, it is the sign of something wrong too. It can be one of a number of various things that we will not go into right here – just speak to a neighborhood plumber please.

Earthquake Straps
Yep, even if you don’t live in an earthquake zone and are required to have these on ones water heater, it is a pretty good idea to do so. It appears like most all new homes in sub-divisions these days have the water heater in the garage. Yes, there is normally a concrete curb in front of it so one does not drive an automobile into it, but things can inadvertently knock it over so be safe and strap that say thanks to in.

Temperature Level Setting
It appears most domestic water heater tanks have setups of warm – hot – extremely hot … and not degree markings. Some “ideas” on conserving energy at home particularly in the winter season time, say to decrease the setting on the tank to 120 degrees. That’s significant for saving energy however legionella microorganisms, which triggers Legionnaire’s disease can expand at 120 degrees. By breathing in the mist from the water in the shower, one can inhale the microorganisms. Look for a medium in between 130 and 120 degrees. Above 130 degrees is technically a scalding temperature so be careful.

Anode Rods
These typically are made from aluminum and there is nothing incorrect with that in theory, though we suggest utilizing magnesium ones. Let’s state for whatever reason there is some sort of emergency or disaster where one lives and one had to make use of the water in the water heater for drinking water (because great deals of emergency preparedness people recommend doing this). The water that comes out of the drain valve is the water at the bottom of the tank. If one has aluminum anodes, that water will be laden with aluminum compounds, which is not great for the human body. It is bad for the stomach, intestines and joints.

The anodes aid with rust defense and are essential in lengthening the life of the water heater. They can also aid with smell troubles with the water. Overall, magnesium anodes simply work better for lots of different reasons like the health advantages, let build up of sediment, a quieter water heater, and they often work better with softened water.

Drain Valve
Ok, simply check it a minimum of yearly to ensure the darn thing opens and works. And it is great to drain and purge the tank at least once a year anyhow (something you obviously are doing already). If for some reason one requires to make use of the water during a disaster or drain it to rather a loud tank and have not drained it frequently, and it does not open, it will take longer to fix the trouble you are at first attempting to repair.

Combustion Changer Hatch
Given that gas and oil water heaters breathe the air drawn in from below, combust with it and exhale it, it is necessary to keep the area around it, specifically below the water heater, clean and swept. If if is not burning properly, it can cause drafting issues (discussed above), as well as combustion and fume issues and potentially be a fire threat. A few of examining the chamber and how the flame burns is objective so we are not going to enter a lot of information here. it is very important to see if the combustion chamber roof has a great deal of rust or water markings or is black in color. These are not an excellent indication at all. One ought to see some blue flame at the bottom when it burns and orange and yellow at the top, however, the yellow ought to not be super high up. One need to see grey metal, some white condensation marks are ok.